[z_calibration] nozzle_xy_position: 231,349 # A X, Y coordinate (e.g. 100,100) of the nozzle, clicking on the z endstop. switch_xy_position: 225,327 # A X, Y coordinate (e.g. 100,100) of the probe's switch body, clicking on # the z endstop. #switch_xy_offsets: optional when switch_xy_position is used # Instead of an absolute position (switch_xy_position), this configuration # adds an X, Y offset (e.g. -6,-18) to the nozzle position. bed_xy_position: 175,175 # A X, Y coordinate (e.g. 100,100) where the print surface (e.g. the center # point) is probed. These coordinates are adjusted by the # probe's X and Y offsets. The default is the zero_reference_position which # replaces the deprecated relative_reference_index # of the configured bed_mesh, if configured. It's possible to change the zero # reference position at runtime or use the GCode argument BED_POSITION of CALIBRATE_Z. wiggle_xy_offsets: 0,0 # After probing the nozzle and retracting, move x some distance away and # back. Useful to prevent the z endstop pin sticking to the nozzle and # being pulled out of the assembly. Can be negative. Defaults to zero to # disable it. Can be combined in x and y to move diagonally. Be careful # to not move your nozzle out of range! switch_offset: 0.51 # The trigger point offset of the used mag-probe switch. # A larger value will position the nozzle closer to the bed. # This must be determined manually. More on this later # in this section.. offset_margins: -1.0,1.0 # The minimum and maximum margins allowed for the calculated offset. # If the offset is outside these values, it will stop! # The margin can be defined as "min,max" e.g. "-0.5,1.5" or by just one # value e.g. "1.0" which translates to "-1.0,1.0" (which is also the default). #max_deviation: DEPRECATED - please use offset_margins instead! # The maximum allowed deviation of the calculated offset. # If the offset exceeds this value, it will stop! # The default is 1.0 mm. #samples: default from "probe:samples" section # The number of times to probe each point. The probed z-values # will be averaged. The default is from the probe's configuration. #samples_tolerance: default from "probe:samples_tolerance" section # The maximum Z distance (in mm) that a sample may differ from other # samples. The default is from the probe's configuration. #samples_tolerance_retries: default from "probe:samples_tolerance_retries" section # The number of times to retry if a sample is found that exceeds # samples_tolerance. The default is from the probe's configuration. #samples_result: default from "probe:samples_result" section # The calculation method when sampling more than once - either # "median" or "average". The default is from the probe's configuration. #safe_z_height: default is 2 * z_offset from the "probe:z_offset" section # The absolute z position in mm to move to before moving to the next # position. The default is two times the z_offset from the probe's # configuration. The minimum safe z height is 3mm. #clearance: DEPRECATED - please use safe_z_height instead! # The distance in mm to move up before moving to the next # position. The default is two times the z_offset from the probe's # configuration. #position_min: default from "stepper_z:position_min" section. # Minimum valid distance (in mm) used for probing move. The # default is from the Z rail configuration. speed: 100 # The moving speed in X and Y. The default is 50 mm/s. #lift_speed: default from "probe:lift_speed" section # Speed (in mm/s) of the Z axis when lifting the probe between # samples and clearance moves. The default is from the probe's # configuration. #probing_speed: default from "stepper_z:homing_speed" section. # The fast probing speed (in mm/s) used, when probing_first_fast # is enabled. The default is from the Z rail configuration. #probing_second_speed: default from "stepper_z:second_homing_speed" section. # The slower speed (in mm/s) for probing the recorded samples. # The default is second_homing_speed of the Z rail configuration. #probing_retract_dist: default from "stepper_z:homing_retract_dist" section. # Distance to retract (in mm) before probing the next sample. # The default is homing_retract_dist from the Z rail configuration. # Caution: if sensorless homing is used on the Z axis with # homing_retract_dist set to zero, this must be set to a value greater zero. probing_first_fast: false # If true, the first probing will be faster by the probing speed. # This is to get down faster and not record the result as a # probing sample. The default is false. start_gcode: Attach_Probe # A list of G-Code commands to run before each calibration command. # See docs/Command_Templates.md for the G-Code format. This can be used to # attach the probe. before_switch_gcode: # A list of G-Code commands to run before to each probing on the # mag-probe. See docs/Command_Templates.md for the G-Code format. This can # be used to attach the probe after probing on the nozzle and before probing # on the mag-probe. end_gcode: Dock_Probe # A list of G-Code commands to run after each calibration command. # See docs/Command_Templates.md for the G-Code format. This can be used to # detach the probe afterwards.