Autocommit from 2025-11-30 13:37:30
Klipper version: v0.13.0-411-g938300f3 Moonraker version: v0.9.3-128-g960e933 Mainsail version: v2.15.0
This commit is contained in:
621
A4T-Upgrade/klicky-probe.cfg
Normal file
621
A4T-Upgrade/klicky-probe.cfg
Normal file
@@ -0,0 +1,621 @@
|
||||
# This macro was provided by discord user Garrettwp to whom i give my thanks for sharing it with me.
|
||||
# I have tweaked it a lot.
|
||||
#
|
||||
# this macro is based on the great Annex magprobe dockable probe macros "#Originally developed by Mental, modified for better use on K-series printers by RyanG and Trails"
|
||||
# that macro can be found here https://github.com/Annex-Engineering/Annex-Engineering_Other_Printer_Mods/blob/master/All_Printers/Microswitch_Probe/Klipper_Macros/dockable_probe_macros.cfg
|
||||
#
|
||||
# by standing on the shoulders of giants, lets see if we can see further
|
||||
|
||||
[gcode_macro User_Variables]
|
||||
variable_verbose: True # Enable verbose output
|
||||
variable_travel_speed: 200 # how fast all other travel moves will be performed when running these macros
|
||||
variable_dock_speed: 50 # how fast should the toolhead move when docking the probe for the final movement
|
||||
variable_release_speed: 100 # how fast should the toolhead move to release the hold of the magnets after docking
|
||||
variable_z_drop_speed: 20 # how fast the z will lower when moving to the z location to clear the probe
|
||||
variable_home_z_height: 15 # Z when homing
|
||||
|
||||
# if a separate Z endstop switch is in
|
||||
# use, specify the coordinates of the switch here (Voron).
|
||||
# Set to 0 to have the probe move to center of bed
|
||||
variable_z_endstop_x: 231
|
||||
variable_z_endstop_y: 350
|
||||
#variable_z_endstop_x: 0
|
||||
#variable_z_endstop_y: 0
|
||||
|
||||
# location to park the toolhead
|
||||
variable_park_toolhead: True # Enable toolhead parking
|
||||
variable_parkposition_x: 175
|
||||
variable_parkposition_y: 175
|
||||
variable_parkposition_z: 10
|
||||
|
||||
#dock location
|
||||
variable_docklocation_x: 12 # X Dock position
|
||||
variable_docklocation_y: 350 # Y Dock position
|
||||
variable_docklocation_z: 15 # Z dock position
|
||||
variable_dockarmslenght: 30 # Dock arms lenght, toolhead movement necessary to clear the dock arms
|
||||
|
||||
#Umbilical to help untangle the umbilical in difficult situations
|
||||
variable_umbilical_x: 15 #X umbilical position
|
||||
variable_umbilical_y: 15 #Y umbilical position
|
||||
variable_umbilical: False #should we untabgle the umbilical
|
||||
|
||||
# Do not modify below
|
||||
gcode:
|
||||
{% set Mx = printer['configfile'].config["stepper_x"]["position_max"]|float %}
|
||||
{% set My = printer['configfile'].config["stepper_y"]["position_max"]|float %}
|
||||
{% set Ox = printer['configfile'].config["probe"]["x_offset"]|float %}
|
||||
{% set Oy = printer['configfile'].config["probe"]["y_offset"]|float %}
|
||||
{% set Oz = printer['configfile'].config["probe"]["z_offset"]|float %}
|
||||
|
||||
# if docklocation_z is zero, use Home Z height for safety
|
||||
{% if docklocation_z == 0 %}
|
||||
SET_GCODE_VARIABLE MACRO=Probe_Variables VARIABLE=docklocation_z VALUE={ home_z_height }
|
||||
{% endif %}
|
||||
|
||||
# If x, y coordinates are set for z endstop, assign them
|
||||
{% if z_endstop_x != 0 or z_endstop_y != 0 %}
|
||||
SET_GCODE_VARIABLE MACRO=Probe_Variables VARIABLE=z_endstop_x VALUE={ z_endstop_x }
|
||||
SET_GCODE_VARIABLE MACRO=Probe_Variables VARIABLE=z_endstop_y VALUE={ z_endstop_y }
|
||||
|
||||
# if no x, y coordinates for z endstop, assume probe is endstop and move toolhead to center of bed
|
||||
{% else %}
|
||||
SET_GCODE_VARIABLE MACRO=Probe_Variables VARIABLE=z_endstop_x VALUE={ (Mx * 0.5) - Ox }
|
||||
SET_GCODE_VARIABLE MACRO=Probe_Variables VARIABLE=z_endstop_y VALUE={ (My * 0.5) - Oy }
|
||||
{% endif %}
|
||||
|
||||
|
||||
[gcode_macro Probe_Variables]
|
||||
variable_probe_attached: False
|
||||
variable_probe_state: False
|
||||
variable_probe_lock: False
|
||||
variable_z_endstop_x: 0
|
||||
variable_z_endstop_y: 0
|
||||
gcode:
|
||||
|
||||
|
||||
[gcode_macro Homing_Variables]
|
||||
#default_parameter_reset: 0
|
||||
gcode:
|
||||
{% set R = params.RESET|default(0)|float %}
|
||||
|
||||
{% if R %}
|
||||
SET_GCODE_VARIABLE MACRO=Probe_Variables VARIABLE=probe_lock VALUE={ False }
|
||||
{% endif %}
|
||||
|
||||
# Attach probe and lock it
|
||||
[gcode_macro Attach_Probe_Lock]
|
||||
gcode:
|
||||
Attach_Probe
|
||||
SET_GCODE_VARIABLE MACRO=Probe_Variables VARIABLE=probe_lock VALUE={ True }
|
||||
|
||||
|
||||
# Dock probe and lock it
|
||||
[gcode_macro Dock_Probe_Unlock]
|
||||
gcode:
|
||||
SET_GCODE_VARIABLE MACRO=Probe_Variables VARIABLE=probe_lock VALUE={ False }
|
||||
Dock_Probe
|
||||
|
||||
# Unlock Probe
|
||||
[gcode_macro Probe_Unlock]
|
||||
gcode:
|
||||
SET_GCODE_VARIABLE MACRO=Probe_Variables VARIABLE=probe_lock VALUE={ False }
|
||||
|
||||
# Lock Probe
|
||||
[gcode_macro Probe_Lock]
|
||||
gcode:
|
||||
SET_GCODE_VARIABLE MACRO=Probe_Variables VARIABLE=probe_lock VALUE={ True }
|
||||
# Attach Probe Routine
|
||||
[gcode_macro Attach_Probe]
|
||||
gcode:
|
||||
# Get probe attach status
|
||||
{% set P = printer["gcode_macro Probe_Variables"].probe_attached %}
|
||||
{% set L = printer["gcode_macro Probe_Variables"].probe_lock %}
|
||||
{% set V = printer["gcode_macro User_Variables"].verbose %}
|
||||
# Get Docking location
|
||||
{% set Dx = printer["gcode_macro User_Variables"].docklocation_x %}
|
||||
{% set Dy = printer["gcode_macro User_Variables"].docklocation_y %}
|
||||
{% set Dz = printer["gcode_macro User_Variables"].docklocation_z %}
|
||||
{% set Da = printer["gcode_macro User_Variables"].dockarmslenght %}
|
||||
# Safe Z for travel
|
||||
{% set Hzh = printer["gcode_macro User_Variables"].home_z_height|float %}
|
||||
#Set speed
|
||||
{% set St = printer["gcode_macro User_Variables"].travel_speed * 60 %}
|
||||
|
||||
#prior to saving actual position, check if its necessary to move to a safe Z
|
||||
#that has enought overhead for the attached probe
|
||||
{% if (printer.toolhead.position.z < Hzh) %}
|
||||
G1 Z{Hzh} F1200
|
||||
{% endif %}
|
||||
M400 # mandatory to save the new safe position
|
||||
#allows the docking position to be independent of the Z offset, necessary for bed mounted probes
|
||||
SAVE_GCODE_STATE name=_attachProbe
|
||||
SET_GCODE_OFFSET Z=0
|
||||
|
||||
# if x and y are not homed
|
||||
{% if not 'xy' in printer.toolhead.homed_axes %}
|
||||
{ action_raise_error("Must Home X and Y Axis First!") }
|
||||
|
||||
# If probe not attached and locked
|
||||
{% elif not P and not L %}
|
||||
{% if V %}
|
||||
{ action_respond_info("Attaching Probe") }
|
||||
{% endif %}
|
||||
G90
|
||||
|
||||
{% if (not 'z' in printer.toolhead.homed_axes) %}
|
||||
{% if V %}
|
||||
{ action_respond_info("Resetting Z position to zero") }
|
||||
{% endif %}
|
||||
SET_KINEMATIC_POSITION Z=0
|
||||
{% endif %}
|
||||
|
||||
{% if (printer.toolhead.position.z < Hzh) %}
|
||||
G1 Z{Hzh} F1200
|
||||
{% endif %}
|
||||
|
||||
Umbilical_Path
|
||||
|
||||
# Probe entry location
|
||||
G1 X{Dx} Y{Dy|int - Da|int} Z{Hzh} F{St}
|
||||
#lower to Z dock
|
||||
G1 Z{Dz} F600
|
||||
# pickup from Probe location
|
||||
G1 X{Dx} Y{Dy} F1800
|
||||
# Probe entry location
|
||||
G1 X{Dx} Y{Dy|int - Da|int} F6000
|
||||
#Go to Z safe distance
|
||||
G1 Z{Hzh} F600
|
||||
Park_Toolhead
|
||||
|
||||
CheckProbe action=attach
|
||||
|
||||
{% elif L %}
|
||||
{% if V %}
|
||||
{ action_respond_info("Probe locked!") }
|
||||
{% endif %}
|
||||
|
||||
# Probe attached, do nothing
|
||||
CheckProbe action=query
|
||||
|
||||
{% else %}
|
||||
{% if V %}
|
||||
{ action_respond_info("Probe already attached!") }
|
||||
{% endif %}
|
||||
|
||||
# Probe attached, do nothing
|
||||
CheckProbe action=query
|
||||
|
||||
{% endif %}
|
||||
#reverts to the original Z offset
|
||||
RESTORE_GCODE_STATE name=_attachProbe
|
||||
|
||||
|
||||
# Dock Probe Routine
|
||||
[gcode_macro Dock_Probe]
|
||||
gcode:
|
||||
# Get probe attach status
|
||||
{% set P = printer["gcode_macro Probe_Variables"].probe_attached %}
|
||||
{% set L = printer["gcode_macro Probe_Variables"].probe_lock %}
|
||||
{% set V = printer["gcode_macro User_Variables"].verbose %}
|
||||
# Get Docking location
|
||||
{% set Dx = printer["gcode_macro User_Variables"].docklocation_x %}
|
||||
{% set Dy = printer["gcode_macro User_Variables"].docklocation_y %}
|
||||
{% set Dz = printer["gcode_macro User_Variables"].docklocation_z %}
|
||||
{% set Da = printer["gcode_macro User_Variables"].dockarmslenght %}
|
||||
# Safe Z for travel
|
||||
{% set Hzh = printer["gcode_macro User_Variables"].home_z_height|float %}
|
||||
# Set speed
|
||||
{% set St = printer["gcode_macro User_Variables"].travel_speed * 60 %}
|
||||
{% set Sd = printer["gcode_macro User_Variables"].dock_speed * 60 %}
|
||||
{% set Sr = printer["gcode_macro User_Variables"].release_speed * 60 %}
|
||||
{% set Sz = printer["gcode_macro User_Variables"].z_drop_speed * 60 %}
|
||||
|
||||
M400 # mandatory to save the new safe position
|
||||
#allows the docking position to be independent of the Z offset, necessary for bed mounted probes
|
||||
SAVE_GCODE_STATE name=_dockProbe
|
||||
SET_GCODE_OFFSET Z=0
|
||||
|
||||
{% if not 'xyz' in printer.toolhead.homed_axes %}
|
||||
{ action_raise_error("Must Home X, Y and Z Axis First!") }
|
||||
|
||||
# If probe not attached and not locked
|
||||
{% elif P and not L %}
|
||||
{% if V %}
|
||||
{ action_respond_info("Docking Probe") }
|
||||
{% endif %}
|
||||
G90
|
||||
|
||||
{% if (printer.toolhead.position.z < Hzh) %}
|
||||
G1 Z{Hzh} F{Sz}
|
||||
{% endif %}
|
||||
|
||||
Umbilical_Path
|
||||
|
||||
# Probe entry location
|
||||
G1 X{Dx} Y{Dy|int - Da|int} Z{Hzh} F{St}
|
||||
#lower to Z dock
|
||||
G1 Z{Dz} F{Sz}
|
||||
# Drop Probe to Probe location
|
||||
G1 X{Dx} Y{Dy} F{Sd}
|
||||
# Probe decoupling
|
||||
G1 X{Dx|int + 40} Y{Dy} F{Sr}
|
||||
#Go to Z safe distance
|
||||
G1 X{Dx|int + 40} Y{Dy|int - 5} Z{Hzh} F{St}
|
||||
|
||||
Park_Toolhead
|
||||
|
||||
CheckProbe action=dock
|
||||
|
||||
{% elif L %}
|
||||
{% if V %}
|
||||
{ action_respond_info("Probe locked!") }
|
||||
{% endif %}
|
||||
|
||||
# Probe docked, do nothing
|
||||
CheckProbe action=query
|
||||
|
||||
{% else %}
|
||||
{% if V %}
|
||||
{ action_respond_info("Probe already docked!") }
|
||||
{% endif %}
|
||||
|
||||
# Probe docked, do nothing
|
||||
CheckProbe action=query
|
||||
|
||||
{% endif %}
|
||||
#reverts to the original Z offset
|
||||
RESTORE_GCODE_STATE name=_dockProbe
|
||||
|
||||
|
||||
|
||||
# Quad Gantry Level
|
||||
[gcode_macro QUAD_GANTRY_LEVEL]
|
||||
rename_existing: _QUAD_GANTRY_LEVEL
|
||||
gcode:
|
||||
BED_MESH_CLEAR
|
||||
{% set V = printer["gcode_macro User_Variables"].verbose %}
|
||||
{% if V %}
|
||||
{ action_respond_info("QG Level") }
|
||||
{% endif %}
|
||||
|
||||
CheckProbe action=query
|
||||
Attach_Probe
|
||||
|
||||
_QUAD_GANTRY_LEVEL {% for p in params
|
||||
%}{'%s=%s ' % (p, params[p])}{%
|
||||
endfor %}
|
||||
Dock_Probe
|
||||
|
||||
|
||||
# Z Tilt Adjust
|
||||
#[gcode_macro Z_TILT_ADJUST]
|
||||
#rename_existing: _Z_TILT_ADJUST
|
||||
#gcode:
|
||||
# {% set V = printer["gcode_macro User_Variables"].verbose %}
|
||||
# {% if V %}
|
||||
# { action_respond_info("Z Tilt Adjust") }
|
||||
# {% endif %}
|
||||
#
|
||||
# CheckProbe action=query
|
||||
# Attach_Probe
|
||||
#
|
||||
# _Z_TILT_ADJUST {% for p in params
|
||||
# %}{'%s=%s ' % (p, params[p])}{%
|
||||
# endfor %}
|
||||
# G28 Z0
|
||||
# Dock_Probe
|
||||
|
||||
|
||||
# Screws Tilt Adjust
|
||||
#gcode_macro SCREWS_TILT_CALCULATE]
|
||||
#rename_existing: _SCREWS_TILT_CALCULATE
|
||||
#gcode:
|
||||
# {% set V = printer["gcode_macro User_Variables"].verbose %}
|
||||
# {% if V %}
|
||||
# { action_respond_info("Screws Tilt Adjust") }
|
||||
# {% endif %}
|
||||
#
|
||||
# CheckProbe action=query
|
||||
# Attach_Probe
|
||||
#
|
||||
# _SCREWS_TILT_CALCULATE {% for p in params
|
||||
# %}{'%s=%s ' % (p, params[p])}{%
|
||||
# endfor %}
|
||||
#
|
||||
# Dock_Probe
|
||||
|
||||
# Bed Mesh Calibrate
|
||||
[gcode_macro BED_MESH_CALIBRATE]
|
||||
rename_existing: _BED_MESH_CALIBRATE
|
||||
gcode:
|
||||
{% set V = printer["gcode_macro User_Variables"].verbose %}
|
||||
{% if V %}
|
||||
{ action_respond_info("Bed Mesh Calibrate") }
|
||||
{% endif %}
|
||||
|
||||
CheckProbe action=query
|
||||
Attach_Probe
|
||||
|
||||
_BED_MESH_CALIBRATE {% for p in params
|
||||
%}{'%s=%s ' % (p, params[p])}{%
|
||||
endfor %}
|
||||
|
||||
Dock_Probe
|
||||
|
||||
|
||||
# Probe Calibrate
|
||||
[gcode_macro PROBE_CALIBRATE]
|
||||
rename_existing: _PROBE_CALIBRATE
|
||||
gcode:
|
||||
{% set Hzh = printer["gcode_macro User_Variables"].home_z_height|float %}
|
||||
{% set Sz = printer["gcode_macro User_Variables"].z_drop_speed * 60 %}
|
||||
{% set St = printer["gcode_macro User_Variables"].travel_speed %}
|
||||
|
||||
# Go to Z safe distance before saving location in order to
|
||||
# avoid crashing the probe on the bed when coming back
|
||||
G1 Z{Hzh} F{Sz}
|
||||
M400 # mandatory to save the new safe position
|
||||
SAVE_GCODE_STATE NAME=_original_nozzle_location
|
||||
|
||||
CheckProbe action=query
|
||||
Attach_Probe
|
||||
|
||||
# Restore nozzle location to probe the right place
|
||||
RESTORE_GCODE_STATE NAME=_original_nozzle_location MOVE=1 MOVE_SPEED={St}
|
||||
|
||||
_PROBE_CALIBRATE {% for p in params
|
||||
%}{'%s=%s ' % (p, params[p])}{%
|
||||
endfor %}
|
||||
|
||||
#store current nozzle location
|
||||
SAVE_GCODE_STATE NAME=_original_nozzle_location
|
||||
Dock_Probe
|
||||
|
||||
# Restore nozzle location again at the end
|
||||
RESTORE_GCODE_STATE NAME=_original_nozzle_location MOVE=1 MOVE_SPEED={St}
|
||||
|
||||
|
||||
# Probe Accuracy
|
||||
[gcode_macro PROBE_ACCURACY]
|
||||
rename_existing: _PROBE_ACCURACY
|
||||
gcode:
|
||||
{% set Hzh = printer["gcode_macro User_Variables"].home_z_height|float %}
|
||||
{% set Sz = printer["gcode_macro User_Variables"].z_drop_speed * 60 %}
|
||||
{% set St = printer["gcode_macro User_Variables"].travel_speed %}
|
||||
|
||||
# Go to Z safe distance before saving location in order to
|
||||
# avoid crashing the probe on the bed when coming back
|
||||
G1 Z{Hzh} F{Sz}
|
||||
M400 # mandatory to save the new safe position
|
||||
SAVE_GCODE_STATE NAME=_original_nozzle_location
|
||||
|
||||
CheckProbe action=query
|
||||
Attach_Probe
|
||||
|
||||
# Restore nozzle location to probe the right place
|
||||
RESTORE_GCODE_STATE NAME=_original_nozzle_location MOVE=1 MOVE_SPEED={St}
|
||||
|
||||
_PROBE_ACCURACY {% for p in params
|
||||
%}{'%s=%s ' % (p, params[p])}{%
|
||||
endfor %}
|
||||
|
||||
#store current nozzle location
|
||||
SAVE_GCODE_STATE NAME=_original_nozzle_location
|
||||
|
||||
Dock_Probe
|
||||
|
||||
# Restore nozzle location again at the end
|
||||
RESTORE_GCODE_STATE NAME=_original_nozzle_location MOVE=1 MOVE_SPEED={St}
|
||||
|
||||
|
||||
# enable to SET_KINEMATIC_POSITION for Z hop
|
||||
[force_move]
|
||||
enable_force_move: True
|
||||
|
||||
# Homeing Override
|
||||
[homing_override]
|
||||
axes: xyz
|
||||
gcode:
|
||||
BED_MESH_CLEAR
|
||||
# collect user state variables
|
||||
User_Variables
|
||||
{% set V = printer["gcode_macro User_Variables"].verbose %}
|
||||
{% set Hzh = printer["gcode_macro User_Variables"].home_z_height|float %}
|
||||
|
||||
{% if (not 'z' in printer.toolhead.homed_axes) %}
|
||||
SET_KINEMATIC_POSITION Z=0
|
||||
G90
|
||||
G0 Z{Hzh} F600
|
||||
{% endif %}
|
||||
|
||||
CheckProbe action=query
|
||||
|
||||
# reset parameters
|
||||
{% set X, Y, Z = False, False, False %}
|
||||
|
||||
# which axes have been requested for homing
|
||||
{% if not 'X' in params
|
||||
and not 'Y' in params
|
||||
and not 'Z' in params %}
|
||||
|
||||
{% set X, Y, Z = True, True, True %}
|
||||
|
||||
{% else %}
|
||||
{% if 'X' in params %}
|
||||
{% set X = True %}
|
||||
{% endif %}
|
||||
|
||||
{% if 'Y' in params %}
|
||||
{% set Y = True %}
|
||||
{% endif %}
|
||||
|
||||
{% if 'Z' in params %}
|
||||
{% set Z = True %}
|
||||
{% endif %}
|
||||
|
||||
{% if 'X' in params
|
||||
and 'Y' in params
|
||||
and 'Z' in params %}
|
||||
# reset homing state variables
|
||||
# if homing all axes
|
||||
Homing_Variables reset=1
|
||||
{% endif %}
|
||||
|
||||
{% endif %}
|
||||
|
||||
# Home x
|
||||
{% if X %}
|
||||
{% if V %}
|
||||
{ action_respond_info("Homing X") }
|
||||
{% endif %}
|
||||
G28 X0
|
||||
{% endif %}
|
||||
|
||||
# Home y
|
||||
{% if Y %}
|
||||
{% if V %}
|
||||
{ action_respond_info("Homing Y") }
|
||||
{% endif %}
|
||||
G28 Y0
|
||||
{% endif %}
|
||||
|
||||
# Home z
|
||||
{% if Z %}
|
||||
{% if V %}
|
||||
{ action_respond_info("Homing Z") }
|
||||
{% endif %}
|
||||
|
||||
# if probe is configured as endstop, attach it
|
||||
{% if printer['configfile'].config["stepper_z"]["endstop_pin"] == 'probe:z_virtual_endstop' %}
|
||||
Attach_Probe
|
||||
{% endif %}
|
||||
|
||||
Home_Z
|
||||
|
||||
#Wipe the nozzle and Home Again
|
||||
#G1 Y350 X85 Z4 F7000
|
||||
#G1 Y348 X115 Z4 F7000
|
||||
#G1 Y350 X85 Z4 F7000
|
||||
#G1 Y348 X115 Z4 F7000
|
||||
#G1 Y350 X85 Z4 F7000
|
||||
#G1 Y348 X115 Z4 F7000
|
||||
#G1 Y350 X85 Z4 F7000
|
||||
#G1 Y348 X115 Z4 F7000
|
||||
CLEAN_NOZZLE
|
||||
Home_Z
|
||||
|
||||
# if probe is configured as endstop, dock it
|
||||
{% if printer['configfile'].config["stepper_z"]["endstop_pin"] == 'probe:z_virtual_endstop' %}
|
||||
Dock_Probe
|
||||
{% endif %}
|
||||
{% endif %}
|
||||
CheckProbe action=query
|
||||
|
||||
# park the toolhead
|
||||
Park_Toolhead
|
||||
|
||||
# umbilical path setup
|
||||
[gcode_macro Umbilical_Path]
|
||||
gcode:
|
||||
{% set Ux = printer["gcode_macro User_Variables"].umbilical_x %}
|
||||
{% set Uy = printer["gcode_macro User_Variables"].umbilical_y %}
|
||||
{% set U = printer["gcode_macro User_Variables"].umbilical %}
|
||||
{% set Hzh = printer["gcode_macro User_Variables"].home_z_height|float %}
|
||||
{% set St = printer["gcode_macro User_Variables"].travel_speed * 60 %}
|
||||
|
||||
{% if U %}
|
||||
# Used to give the umbilical a better path to follow and coil properly if dock is tight in space
|
||||
G1 X{Ux} Y{Uy} Z{Hzh} F{St}
|
||||
{% endif %}
|
||||
|
||||
|
||||
# Home Z Routine
|
||||
[gcode_macro Home_Z]
|
||||
gcode:
|
||||
{% set Zx = printer["gcode_macro Probe_Variables"].z_endstop_x %}
|
||||
{% set Zy = printer["gcode_macro Probe_Variables"].z_endstop_y %}
|
||||
{% set Hzh = printer["gcode_macro User_Variables"].home_z_height|float %}
|
||||
{% set St = printer["gcode_macro User_Variables"].travel_speed * 60 %}
|
||||
{% set Sz = printer["gcode_macro User_Variables"].z_drop_speed * 60 %}
|
||||
|
||||
# if x and y are not homed yet, raise error
|
||||
{% if not 'xy' in printer.toolhead.homed_axes %}
|
||||
{ action_raise_error("Must Home X and Y Axis First!") }
|
||||
|
||||
{% else %}
|
||||
{% if (not 'z' in printer.toolhead.homed_axes) %}
|
||||
{% if V %}
|
||||
{ action_respond_info("Resetting Z position to zero") }
|
||||
{% endif %}
|
||||
SET_KINEMATIC_POSITION Z=0
|
||||
{% endif %}
|
||||
|
||||
# move tool to safe homing position and home Z axis
|
||||
# location of z endstop
|
||||
G1 X{Zx} Y{Zy} Z{Hzh} F{St}
|
||||
G28 Z0
|
||||
G1 Z{Hzh} F{Sz}
|
||||
|
||||
{% endif %}
|
||||
|
||||
|
||||
# check to see if probe is where it is supposed to be after
|
||||
# attaching/docking maneuver and set homing error or shutdown
|
||||
[gcode_macro CheckProbe]
|
||||
variable_probe_state: 0
|
||||
#default_parameter_action:
|
||||
gcode:
|
||||
Query_Probe
|
||||
SetProbeState action={ ACTION }
|
||||
|
||||
|
||||
# due to how templates are evaluated, we have query endstops in one
|
||||
# macro and call another macro to make decisions based on the result
|
||||
[gcode_macro SetProbeState]
|
||||
#default_parameter_action:
|
||||
gcode:
|
||||
{% set P = printer.probe.last_query %}
|
||||
{% set V = printer["gcode_macro User_Variables"].verbose %}
|
||||
|
||||
# If triggered (true), probe not attached
|
||||
{% if P %}
|
||||
SET_GCODE_VARIABLE MACRO=Probe_Variables VARIABLE=probe_attached VALUE={ False }
|
||||
|
||||
# If not triggered (false), probe attached
|
||||
{% else %}
|
||||
SET_GCODE_VARIABLE MACRO=Probe_Variables VARIABLE=probe_attached VALUE={ True }
|
||||
{% endif %}
|
||||
|
||||
{% if params.ACTION == 'query' %}
|
||||
SET_GCODE_VARIABLE MACRO=Probe_Variables VARIABLE=probe_state VALUE={ P }
|
||||
{% endif %}
|
||||
|
||||
# if probe fails to attach/detach
|
||||
# if not docked
|
||||
{% if (not P and params.ACTION == 'dock') %}
|
||||
{ action_raise_error("Probe dock failed!") }
|
||||
{% endif %}
|
||||
|
||||
# if not attached
|
||||
{% if P and params.ACTION == 'attach' %}
|
||||
{ action_raise_error("Probe attach failed!") }
|
||||
{% endif %}
|
||||
|
||||
# Park Toolhead Routine
|
||||
[gcode_macro Park_Toolhead]
|
||||
gcode:
|
||||
{% set P = printer["gcode_macro User_Variables"].park_toolhead %}
|
||||
{% set Px = printer["gcode_macro User_Variables"].parkposition_x %}
|
||||
{% set Py = printer["gcode_macro User_Variables"].parkposition_y %}
|
||||
{% set Pz = printer["gcode_macro User_Variables"].parkposition_z %}
|
||||
{% set St = printer["gcode_macro User_Variables"].travel_speed * 60 %}
|
||||
{% set V = printer["gcode_macro User_Variables"].verbose %}
|
||||
|
||||
{% if (P and 'xyz' in printer.toolhead.homed_axes) %}
|
||||
{% if V %}
|
||||
{ action_respond_info("Parking Toolhead") }
|
||||
{% endif %}
|
||||
G90
|
||||
G1 X{Px} Y{Py} Z{Pz} F{St}
|
||||
{% endif %}
|
||||
|
||||
Reference in New Issue